Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 550 x 600 x 305 | 550 x 600 x 375 |
| Panel Type | Control Panel |
| IP Rating | IP 66 |
| Gas Group | IIA; IIB |
| Brand | SAIEX |
| Certifications | BIS, IS/IEC, PESO / CCOE, CIMFR |
| Material | Aluminum |
| Surface Treatment | Color Coated |
| Usage/Application | Junction Boxes |
| Country of Origin | Made in India |
| Voltage | 550 V AC |
| Temperature Class | T5 |
| Zone | Zone 1/2 & 21/22 |
“SAIEX” flameproof control panel is a special type of electrical control panel designed for hazardous (explosive) environments, where flammable gases, vapors, or dust may be present. Its purpose is to prevent any internal spark, arc, or heat from igniting the surrounding atmosphere.
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Various Names: Explosion Proof Control Panel, Ex d Control Panel (as per IEC/ATEX standards), Hazardous Area Control Panel, Gas-tight Control Panel, Flameproof Electrical Panel.
Gas Group: IIB, Temperature class: T5, Zone: 1/2 & 21/22. IP Protection: IP 65 as per IS/IEC 60529: 2001. Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010)
Gasket: Endless Molded Neoprene. MOC: Cast Aluminium Alloy LM-6
Earthing: 1 nos Inside & 2 nos Outside. Electrical Maximum Rating: 800Amps, 550V AC or upto 230V DC. Marking Plate: (Ex db IIB T5 Gb) (Ex tb IIIC T100°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
SX-1-005-1 |
550 x 600 x 305 |
520 x 570 x 270 |
19 mm |
465 x 515 |
|
SX-1-005-2 |
550 x 600 x 375 |
520 x 570 x 340 |
19 mm |
465 x 515 |
Enclosure Shape: Square.Mounting: On door & base Mount. Cable Entry Size: M20, ½” NPT, ¾” ET. Cable Entry Nos: As per required.
Accessories: Cable Gland, Stopping Plug, Adapter, Reducer, Breather plug. Components: Glass Window, Push Button, POT Switch, Rotary switch, Indicating Lamp, Emergency Stop button, Terminal block.
CERTIFICATES: BIS | CIMFR | PESO. STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Where Are Flameproof Control Panels Used? Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Common Industries: Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants, Sugar, grain, and flour mills.
Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 350 x 350 x 265 | 350 x 350 x 348 |
| Panel Type | Control Panel |
| IP Rating | IP66 |
| Gas Group | IIA; IIB |
| Certifications | PESO / CCOE, CIMFR, BIS |
| Area Classification | Zone 1 & 2 |
| Zone | ZONE 1/2 & ZONE 21/22 |
| Temperature Class | T5 |
“SAIEX” flameproof control panel is a special type of electrical control panel designed for hazardous (explosive) environments, where flammable gases, vapors, or dust may be present. Its purpose is to prevent any internal spark, arc, or heat from igniting the surrounding atmosphere.
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Various Names: Explosion Proof Control Panel, Ex d Control Panel (as per IEC/ATEX standards), Hazardous Area Control Panel, Gas-tight Control Panel, Flameproof Electrical Panel, ATEX Certified Control Panel, Zone 1 / Zone 2 Control Panel.
Gas Group: IIB, Temperature class: T5, Zone: 1/2 & 21/22. IP Protection: IP 66 as per IS/IEC 60529: 2001. Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010)
Gasket: Endless Molded Neoprene; MOC: Cast Aluminium Alloy LM-6; Earthing: 1 nos Inside & 2 nos Outside. Electrical Maximum Rating: 250Amps, 550V AC or upto 230V DC. Marking Plate: (Ex db IIB T5 Gb) (Ex tb IIIC T100°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
SX-1-001-1 |
350 x 350 x 265 |
238 |
15 mm |
290 x 290 |
|
SX-1-001-2 |
350 x 350 x 348 |
324 |
15 mm |
290 x 290 |
Enclosure Shape: Square; Mounting: On door & base Mount. Cable Entry Size: M20, ½” NPT, ¾” ET; Cable Entry Nos: As per required. Accessories: Cable Gland, Stopping Plug, Adapter, Reducer, Breather plug. Components: Glass Window, Push Button, POT Switch, Rotary switch, Indicating Lamp, Emergency Stop button, Terminal block.
CERTIFICATES: BIS | CIMFR | PESO. STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Where Are Flameproof Control Panels Used? Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants, Sugar, grain, and flour mills.
Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 400 x 400 x 250 |
| Panel Type | Control Panel |
| IP Rating | IP66 |
| Gas Group | IIC |
| Certifications | IS/IEC, PESO / CCOE, BIS, CIMFR |
| Temperature Class | T6 |
| Zone | Zone 1/2 & 21/22 |
“SAIEX” flameproof control panel is a special type of electrical control panel designed for hazardous (explosive) environments, where flammable gases, vapors, or dust may be present. Its purpose is to prevent any internal spark, arc, or heat from igniting the surrounding atmosphere.
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths.
Various Names: Explosion Proof Control Panel, Ex d Control Panel (as per IEC/ATEX standards), Hazardous Area Control Panel, Gas-tight Control Panel, Flameproof Electrical Panel, ATEX Certified Control Panel, Zone 1 / Zone 2 Control Panel.
Gas Group: IIC, Temperature class: T6, Zone: 1/2 & 21/22. IP Protection: IP 66 as per IS/IEC 60529: 2001. Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010)
Gasket: Endless Molded Neoprene. MOC: Cast Aluminium Alloy LM-6. Earthing: 1 nos Inside & 2 nos Outside. Electrical Maximum Rating: 250Amps, 550V AC or upto 230V DC
Marking Plate: (Ex db IIC T6 Gb) (Ex tb IIIC T185°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
SX-1-001C-1 |
400 x 400 x 250 |
380 X 380 X 205 |
12 mm |
340 x 340 |
CERTIFICATES: BIS | CIMFR | PESO. STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Electrical components inside the panel (contactors, relays, breakers, PLCs, etc.) may create sparks or heat during normal operation. If a flammable gas enters the enclosure and ignites due to a spark: The enclosure contains the explosion. No rupture or damage occurs. Flame paths (precision machined joints) allow hot gases to escape slowly. By the time gases exit: Their temperature drops below ignition level. The external explosive atmosphere is not ignited
Key Safety Features: Thick-walled metal enclosure. Precision-machined flame paths. Certified cable glands (Ex d). High-temperature resistant gaskets. Proper earthing/grounding
Where Are Flameproof Control Panels Used? Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants, Sugar, grain, and flour mills
Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 453 x 453 x 284 | 453 x 453 x 408 |
| Panel Type | Control Panel |
| IP Rating | IP66 |
| Gas Group | IIA; IIB |
| Certifications | BIS, ATEX, PESO / CCOE, IS/IEC, CIMFR |
| Zone | Zone 1/2 & 21/22 |
| Temperature Class | T5 |
“SAIEX” flameproof control panel is a special type of electrical control panel designed for hazardous (explosive) environments, where flammable gases, vapors, or dust may be present. Its purpose is to prevent any internal spark, arc, or heat from igniting the surrounding atmosphere.
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Gas Group: IIB, Temperature class: T5, Zone: 1/2 & 21/22. IP Protection: IP 66 as per IS/IEC 60529: 2001. Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010)
Gasket: Endless Molded Neoprene. MOC: Cast Aluminium Alloy LM-6. Earthing: 1 nos Inside & 2 nos Outside. Electrical Maximum Rating: 300Amps, 550V AC or upto 230V DC. Marking Plate: (Ex db IIB T5 Gb) (Ex tb IIIC T100°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm |
|
|
SX-1-002-1 |
453 x 453 x 284 |
254 |
10 mm |
390 x 390 |
|
|
SX-1-002-2 |
453 x 453 x 408 |
378 |
10 mm |
390 x 390 |
|
Enclosure Shape: Square. Mounting: On door & base Mount.. Cable Entry Size: M20, ½” NPT, ¾” ET. Cable Entry Nos: As per required. Accessories: Cable Gland, Stopping Plug, Adapter, Reducer, Breather plug. Components: Glass Window, Push Button, POT Switch, Rotary switch, Indicating Lamp, Emergency Stop button, Terminal block.
CERTIFICATES: BIS | CIMFR | PESO. STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Where Are Flameproof Control Panels Used? Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Common Industries: Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants.
Product Details:
| Minimum Order Quantity | 20 Piece |
| Material of Construction (MOC) | Cast Aluminium |
| Material | Aluminium |
| Dimensions (H x W x D) | 186 x 278 x 132 | 215 x 385 x 180 |
| Application | Electronics/Electrical |
| Features | Corrosion Resistant, Waterproof, Temperature Resistant, Fire-Resistant |
| Certifications | IS/IEC, ATEX, BIS, PESO / CCOE, CIMFR |
| Mounting Type | Wall Mount |
| Color | Light Gray |
| Surface Finishing | Powder Coated |
| Rubber Seal | Foamed Neoprene Seal |
| Operating Temperature | -5 Deg. C to 80 Deg. C |
| Ip Rating | IP66 |
| Country of Origin | Made in India |
“SAIEX” flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Gas Group: IIB, Temperature class: T6, Zone: 1/2 & 21/22.
IP Protection: IP 66 as per IS/IEC 60529: 2001.
Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010) Gasket: Endless Molded Neoprene.
MOC: Cast Aluminium Alloy LM-6.
Earthing: 1 nos Inside & 2 nos Outside.
Electrical Maximum Rating: 63Amps, 550V AC or upto 230V DC.
Marking Plate: (Ex db IIB T6 Gb) (Ex tb IIIC T85°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
|
SX-1-003-1 |
186 x 278 x 132 |
130 x 220 x 96 |
6 mm |
120 x 210 |
|
|
SX-1-003-2 |
186 x 278 x 180 |
130 x 220 x 145 |
6 mm |
120 x 210 |
|
|
SX-1-003-3 |
186 x 278 x 160 |
130 x 220 x 125 |
6 mm |
120 x 210 |
|
|
SX-1-003-4 |
186 x 278 x 208 |
130 x 220 x 175 |
6 mm |
120 x 210 |
|
|
SX-1-003-7(OLD) |
200 x 370 x 198 |
150 |
6 mm |
135 x 280 |
|
|
SX-1-003-8(NEW) |
215 x 385 x 180 |
155 x 325 x 155 |
|
135 x 280 |
|
CERTIFICATES: BIS | CIMFR | PESO. STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
Additional Information:
Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 564 x 564 x 223 |
| Panel Type | Control Panel |
| IP Rating | IP66 |
| Gas Group | IIC |
| Certifications | IS/IEC, CIMFR, BIS, PESO / CCOE |
| Zone | Zone 1/2 & 21/22 |
| Temperature Class | T6 |
| Voltage | 550V AC |
| Enclosure Shape | Round |
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Gas Group: IIC, Temperature class: T6, Zone: 1/2 & 21/22. IP Protection: IP 66 as per IS/IEC 60529: 2001.
Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010). Gasket: Endless Molded Neoprene
MOC: Cast Aluminium Alloy LM-6. Earthing: 1 nos Inside & 2 nos Outside.
Electrical Maximum Rating: 160Amps, 550V AC or upto 230V DC.
Marking Plate: (Ex db IIC T6 Gb) (Ex tb IIIC T85°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
SX-1-005C |
564 x 564 x 223 |
175 |
18 mm |
480 x 465 |
Enclosure Shape: Round. Mounting: On door & base Mount. Cable Entry Size: M20, ½” NPT, ¾” ET. Cable Entry Nos: As per required.
Accessories: Cable Gland, Stopping Plug, Adapter, Reducer, Breather plug.
Components:Glass Window, Push Button, POT Switch, Rotary switch, Indicating Lamp, Emergency Stop button, Terminal block.
CERTIFICATES: BIS | CIMFR | PESO. STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Where Are Flameproof Control Panels Used? Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Common Industries: Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants, Sugar, grain, and flour mills
Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 250 x 300 x 148 | 250 x 300 x 173 |
| Panel Type | Control Panel |
| IP Rating | IP65 |
| Gas Group | IIA; IIB |
| Certifications | PESO / CCOE, IS/IEC, BIS, CIMFR, ATEX |
| Zone | Zone 1/2 & 21/22 |
| Temperature Class | T6 |
“SAIEX” flameproof control panel is a special type of electrical control panel designed for hazardous (explosive) environments, where flammable gases, vapors, or dust may be present. Its purpose is to prevent any internal spark, arc, or heat from igniting the surrounding atmosphere.
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Gas Group: IIB, Temperature class: T6, Zone: 1/2 & 21/22.
IP Protection: IP 65 as per IS/IEC 60529: 2001. Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010)
Gasket: Endless Molded Neoprene, MOC: Cast Aluminium Alloy LM-6.
Earthing: 1 nos Inside & 2 nos Outside,
Electrical Maximum Rating: 125Amps, 550V AC or upto 230V DC. Marking Plate: (Ex db IIB T6 Gb) (Ex tb IIIC T85°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
SX-1-004-1 |
250 x 300 x 148 |
230 x 275 x 125 |
8 mm |
200 x 250 |
|
SX-1-004-2 |
250 x 300 x 173 |
230 x 275 x 150 |
8 mm |
200 x 250 |
CERTIFICATES: BIS | CIMFR | PESO.
STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Where Are Flameproof Control Panels Used?
Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Common Industries: Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants, Sugar, grain, and flour mills
Product Details:
| Material of Construction (MOC) | Cast Aluminium |
| Dimensions (H x W x D) | 250 x 250 x 180 | 250 x 250 x 220 |
| Usage/Application | INDUSTRIAL |
| Panel Type | Control Panel |
| Switch Type | Vary As per Requirement |
| IP Rating | IP66 |
| Gas Group | IIC |
| Color | Vary As per Requirement |
| Certifications | PESO / CCOE, BIS, IS/IEC, CIMFR |
| Material/Body | Aluminum |
| Brand | SAIEX |
| Voltage | 550V AC |
| Zone | Zone 1/2 & 21/22 |
| Temperature Class | T6 |
“SAIEX” flameproof control panel is a special type of electrical control panel designed for hazardous (explosive) environments, where flammable gases, vapors, or dust may be present. Its purpose is to prevent any internal spark, arc, or heat from igniting the surrounding atmosphere.
A flameproof control panel is an enclosed electrical panel built with a strong, rigid housing (usually cast aluminium or steel) that: Contains explosions inside the enclosure. Prevents flames from escaping to the outside atmosphere. Allows hot gases to cool before exiting through flame paths. Even if an electrical fault causes an internal explosion, the enclosure ensures the external hazardous atmosphere is not ignited.
Gas Group: IIC, Temperature class: T6, Zone: 1/2 & 21/22.
IP Protection: IP 66 as per IS/IEC 60529: 2001.
Colour: Epoxy Grey 631 (Other option Pebble Grey 7032, 7035 & Pure White 9010)
Gasket: Endless Molded Neoprene. MOC: Cast Aluminium Alloy LM-6
Earthing: 1 nos Inside & 2 nos Outside.
Electrical Maximum Rating: 125Amps, 550V AC or upto 230V DC.
Marking Plate: (Ex db IIC T6 Gb) (Ex tb IIIC T85°C Db)
|
MODEL NO. |
SIZE (W x H x D) (mm) |
INTERNAL DIMENSION (W x H x D) (mm) |
WALL THICKNESS |
BASE PLATE (mm) |
|
SX-1-004C-1 |
250 x 250 x 180 |
145 |
12 mm |
200 x 210 |
|
SX-1-004C-2 |
250 x 250 x 220 |
180 |
12 mm |
200 x 210 |
Enclosure Shape: Round.
Mounting: On door & base Mount..
Cable Entry Size: M20, ½” NPT.
Cable Entry Nos: As per required.
Accessories: Cable Gland, Stopping Plug, Adapter, Reducer, Breather plug.
Components: Glass Window, Push Button, POT Switch, Rotary switch, Indicating Lamp, Emergency Stop button, Terminal block.
CERTIFICATES: BIS | CIMFR | PESO.
STANDARDS: IS/lEC 60079-0:2017 | IS/lEC 60079-1:2014| IS/lEC 60019-31:2013
How Does a Flameproof Control Panel Work?
Where Are Flameproof Control Panels Used?
Flameproof panels are used in hazardous locations where explosive atmospheres may exist. Common Industries: Oil & Gas plants, Petrochemical industries, Refineries, Chemical processing plants, Pharmaceutical industries, Paint and solvent plants, Coal mines, Power plants, Sugar, grain, and flour mills
Product Details:
| Minimum Order Quantity | 5 Piece |
| Type of Control Panel | FLP |
| Brand | SAIEX |
| Material | Cast Aluminum |
| Usage/Application | Industrial |
| Country of Origin | Made in India |
| Voltage | 550V AC |
Additional Information: